Effective: 1-09-12 40 L-2655
Repl Comp
Model Comp Model p/n mfd/volts p/n mfd/volts p/n model
RM24C 3015026
ZR26K3-PFV-130
4040140 40/370 4040206 88-106 330V 4130150 3ARR3CT3P5
RM30C 3015030
ZR30KC-PFV-130
331475 35/440 4040206 88-106 330V 4130150 3ARR3CT3P5
RM42C 3015042
ZR42K3-PFV-130
4040155 55/370 4040206 88-106 330V 4130150 3ARR3CT3P5
RM24CK 3015330
ZR30K3-PFJ-130
4040145 45/370 4040206 88-106 330V 4130150 3ARR3CT3P5
RM30CK N/A
ZR36K3-PFJ-130
4040150 50/370 4040206 88-106 330V 4130150 3ARR3CT3P5
RM42CK 3015348
ZR48K3-PFJ-130
4040160 60/370 331733 270-324/330 335355 3ARR3CT4D5
RM24D(C) 3015126
ZR26K3-TF5-130
RM30D(C) 3015130
ZR30K3-TF5-130
RM42D(C) 3015142
ZR42K3-TF5-130
RM24E(C) N/A
ZR26K3-TFD-130
RM30E(C) 3015230
ZR30K3-TFD-130
RM42E(C) 3015242
ZR42K3-TFD-130
RM24ECK 3015230
ZR30K3-TFD-130
115V Coil 4130830
RM30ECK 3015236
ZR36K3-TFD-130
230V coil 4130630
RM42ECK 3015248
ZR48K3-TFD-130
Condenser Seawater Manifolds
RM24 720243000 water in
RM24 701824301 RM24 720243001 water out
RM30 N/A RM30 720303600 in/out (order qty 2)
RM42 701842482 RM42 720424800 in/out (order qty 2)
Repl Comp
Model Comp Model p/n mfd/volts p/n mfd/volts p/n model
FM24C 3000126
ZR22KC-PFV-130 331475 35UF
4040206 88-106 330V
4130150 3ARR3CT3P5
F
M42C
3015036
ZR36KC-PFV-130
4040140 40/370 4040206 88-106 330V 4130150 3ARR3CT3P5
FM24CK
335804
ZR24K3-PFJ-130
4040140 40/370 4040206 88-106 330V 4130150 3ARR3CT3P5
FM42CK
3015342
ZR42K3-PFJ-130 4040155 55UF
4040206 88-106 330V 4130150 3ARR3CT3P5
FM24D(C)
3015119
ZR22K3-TF5-130
FM42D(C)
334365
ZR36K3-TF5-130
FM24E(C)
N/A
ZR22K3-TFD-230
FM42E(C)
3015236
ZR36K3-TFD-130
FM24ECK
N/A
ZR24K3-TFD-130
FM42ECK
3015248
ZR49K3-TFD-250
Notes:
Repl Cond.
Model Rev Valve 115V 230V Coil
F5
R3600-F5
F7
R3600-F7
F10
R3600-F10
F12
R3600-F12
F16 A-509C 4071502 4071602
R3600-F16
F20
R3600-F20
F24
R3600-F24
F30
R3600-F30
F36
R3600-F36
F16 A-510B - 4071602
R3600-F48
Notes:
1. High pressure switch for WFAH and J units: A-200
2. High pressure switch for F, FX, JX, and FN units: A-205
3. Low pressure switch for F, FX, JX, and FN units: A-201
4. On older models with soldered cap tube pressure switches, use assembly A-516 with a switch above.
Reversing Valve Note : Before ordering a Reversing Valve or coil, see the 'Replacement Reversing Valves" section of this book, and
Field Notice #FNR233-I4. For older units you must order a new solenoid coil with the new reversing valve.
Start Capacitor Start Relay
"RM" Type Remote Modulating Condensing Unit Replacement Parts
Run Capacitor
A-512B - 4071602
A-509C 4071502 4071602
A-511B - 4071602
A-509B 4071501 4071601
Solenoid Coils
Replacement Condensers Assemblies
Old "FM" Type Modulating Condensing Unit Replacement Parts
Contactors for 3 Phase Compressors only
All D & E models with 115V control
All DC & EC models with 230V control
the existing parts before ordering.
2. F20C-48ECK (1ph and 3ph) models have used various compressors throughout the years. For replacement start components, check
Old "F" Type Remote Condensing Unit Replacement Parts
1. All F5-F16CK models (includes WFAH, FX, FN, J models))use the same replacement compressors, start components and reversing
valves as the "R" type units in the chart on previous page.