Effective: 1-09-12 38 L-2655
StowAway V Replacement Parts - Recip. Compressors
Capacity Start Rev. Rev.Valve Repl. Repl. Comp.
Model (Btu/hr) Run Start Relay Valve Solenoid Condenser Compressor Overload
115V
SH,SX7 7,000 4040115 330412 4130150 A-509B 4071501 R3600-S7 293045657 048800
SH,SX10 10,000 333360 330412 4128325 A-511B 4071502 R3600-S10 R3101-10S 048900
SH,SX12 12,000 333360 4040543 4130150 A-511B 4071502 R3600-S12 293045656 049000
SH,SX16 16,000 331475 4040543 4130150 A-511B 4071502 R3600-S16 293045644 331404
230V
SH,SX7C 7,000 4040115 330412 4128425 A-509B 4071601 R3600-S7 R3102-7S 048400
SH,SX10C 10,000 4040115 330412 4130150 A-511B 4071602 R3600-S10 R3102-10S 049200
SH,SX12C 12,000 4040115 4040543 4130150 A-511B 4071602 R3600-S12 R3102-12S 049300
SH,SX16C 16,000 338455 4040543 4130150 A-511B 4071602 R3600-S16 293045645 331405
SH,SX24C 24,000 4040130 330559 4130150 A-510B 4071602 N/A 293045653* Internal
SH,SX24C3* 24,000 333360 4040206 4130200 A-510B 4071602 N/A 293045653* Internal
220-240V 50Hz
SH,SX7CK 7,000 4040115 330412 4130150 A-509B 4071601 R3600-S7 R3103-7S 046500
SH,SX10CK 10,000 4040115 330412
4130150 A-511B 4071602 R3600-S10 N/A 046600
SH,SX12CK 12,000 4040115 4040543 4130150 A-511B 4071602 R3600-S12 R3103-12S 046700
SH,SX16CK 16,000 333360 4040543 4130200 A-511B 4071602 R3600-S16 R3103-16S N/A
SH,SX24CK 24,000 331475 330559 4130200 A-510B 4071602 N/A 293045653* Internal
SH,SX24CK3* 24,000 331475 4040206 4130200 A-510B 4071602 N/A 293045653* Internal
Note: Model numbers ending in "3" use H23 compressors. Replacement compressors ending in "3" include both capacitors and
the start relay.
StowAway V Replacement Parts - Rotary Compressors
Capacity Start Rev. Rev.Valve Repl. Repl. Comp.
Model (Btu/hr) Run Start* Relay* Valve Solenoid Condenser Compressor Overload
115V
SHR, SXR7 7,000 4040115 330559 4130150 A-509B 4071501 R3600-S7 293045660 332849
SHR, SXR10 10,000 4040130 330559 4130150 A-511B 4071502 R3600-S10 293045651 332852
SHR, SXR12 12,000 4040130 330559 4130150 A-511B 4071502 R3600-S12 293045655 332855
SHR, SXR16 16,000 4040130 330559 4130150 A-511B 4071502 R3600-S16 293045642 332858
230V
SHR, SXR7C 7,000 4040140 330559 4130150 A-509B 4071601 R3600-S7 293045660 332851
SHR, SXR10C 10,000 4040130 330559 4130150 A-511B 4071602 R3600-S10 293045659 046807
SHR, SXR12C 12,000 4040130 330559 4127400
A-511B
4071602 R3600-S12 293045672 046801
SHR, SXR16C 16,000 4040130 330559 4127400 A-511B 4071602 R3600-S16 293045652 046801
220-240V 50Hz
SHR, SXR7CK 7,000 4040115 - - A-509B 4071601 R3600-S7 R3142-7S 044600
SHR, SXR10CK 10,000 4040130 330559 4127500 A-511B 4071602 R3600-S10 N/A 046808
SHR, SXR12CK 12,000 4040130 330559 4127500 A-511B 4071602 R3600-S12 R3142-12S 046805
SHR, SXR16CK 16,000 4040130 330559 4127500 A-511B 4071602 R3600-S16 293045673 046801
Note: Newer SXR SMXII rotary units use a PTCR start assist (# 335055) instead of a start capacitor and start relay, except for
7k models which have no start assist device. The customer will need to know whether or not their unit has either the Start
Cap & Relay or the PTCR.
Notes:
1. High pressure switch for SH and SHR units: A-200 (line duty)
2. High pressure switch for SX and SXR units: A-205
3. Low pressure switch for SX and SXR units: A-201
Reversing Valves & Solenoid Coils:
See "Replacement Reversing Valves" section of this book and Field Notice #FNR233-l4
before ordering RV's or Coils. When ordering a new RV for an old unit, you must also order a new coil and vice versa.
Capacitors
Capacitors