SPECIFICATIONSANDINSTALLATIONINSTRUCTIONS
INSTALLATIONGUIDELINES
Installationmustbeinaccordancewithallapplicablestandards.Follow ABYCstandardsformarineuseandRVIA
standardsforRVuse.Otherinstallationsmayhaveotherrequirements.Installationshouldbeperformedby
qualifiedpersonsonly!
DimensionsandSpecifications
Overall117/8"L x125/8"Wx31/32"D
mm301L x320Wx77D
Cutout1 /8"L x11 / Wx35/32"D
mm L x Wx80D
Powerrequirements
120V60Hz1200W10 A 15 A breaker
220-240V50Hz1100W4.8 A 10A breaker
240V50Hz1200W5 A 10 A breaker
Dimensions and Specifications
Overall211/16"L x117/8"Wx31/32"D
mm535L x301Wx77D
Cutout20 / "L x1 /8"Wx35/32"D
mm L x Wx80D
Powerrequirements
120V60Hz2400W20 A 25 A breaker
220-240V50Hz2200W9.6 A 15 A breaker
240V50Hz2400W10 A 15A breaker
Dimensions and Specifications
Overall205/8"L x191/8"Wx31/32"D
mm524L x486Wx77D
Cutout "L x18 /8"Wx35/32"D
mm L x Wx80D
Powerrequirements
120V60Hz3600W30 A 35 A breaker
220-240V50Hz3300W14.4 A 20 A breaker
240V50Hz3600W15 A 20 A breaker
Important Saveforthelocalelectricalinspector'suse.
Thecooktopcanbeinstalledonlyincoveredpremiseswithanormalfire
safeguard. Thetemperatureinthepremisesshouldbewithinthelimitsfrom
Thecooktopshouldbeinstalledinalocationappropriateforeasy
useandsafeoperation. A minimumclearanceof3-4inches(76-102mm)should
bemaintainedinalldirections. Theapplianceshouldbepreservedfromadirect
splashingbywaterorotherliquids.
Toeliminatetheriskofburnsorfirebyreachingoverheatedsurfaceunits,
cabinetstoragespacelocatedabovethesurfaceunitsshouldbeavoided.If
cabinetstorageistobeprovided,theriskcanbereducedbyinstallingarange
hoodthatprojectshorizontallyaminimumof5inchesbeyondthebottomofthe
cabinets. Thedistancetothehood,woodenormetalcabinetshouldbeatleast
30inches(762mm).
Therequiredminimaldistancestoneighboringsurfacesshouldbeobserved.
Normalinstallationoftheappliancerequiresacutoutinthecountertopofadimensionindicatedinthe
specifications.Insurethereisnointerferencebelowthecountertoppriortocutting.
Allowforproperventilationbeneaththecountertop. A minimumof3-sq.in.perburnerisrecommended.
E300-3burnerX3=9sq.intotal.)Failuretoprovideadequateventilationmayresultinpoor
performanceandisapotentialfirehazard.Inaddition,inadequateventilationoftheOrigocooktopmayaffectproper
operationofanadjacentbuilt-inappliance.
A threeconductor,tinnedstrandedmarine-typecableissuppliedwiththeapplianceforconnectionto ACelectrical
currentonly.Checkthelabelontheproducttoinsurethatthevoltageoftheunitmatchesthevoltageofthesource.
ModelE100
Model E200
Model E300
11 78
282 301
516 11
516 282
20 3
508 467
5
upto40ºC.
(Example:Model
Theceramiccooktopm besecuredtothecountertopasthemetalframeshouldbebeddedtothe
countertopusinganon-hardeningcompoundwhichshouldbelaidbetweentheglass-ceramicandthe
countertopandshouldpermitlaterremovaloftheappliancewithoutdamageifservicenecessary.
ust
117/8(301mm)
103/8(264mm)
27/8(72mm)
125/8(320mm)
111/8(283mm)
31/32(77mm)
211/16(535mm)
195/8(498mm)
27/8(72mm)
117/8(301mm)
103/8(264mm)
31/32(77mm)
205/8(524mm)
197/32(488mm)
27/8
(72mm)
191/8(486mm)
175/8(448mm)
31/32(77mm)
30(762mm)
minimum
5/8(16mm)
minimum
3(76mm)
minimum
3(76mm)
minimum
Datalabel